| THIS EXAMPLE WILL NOT WORK AS IT IS - YOU MUST SPECIFY YOUR OWN VALUES!!!
 | |
| 
 | |
| This file is organized around the "Conference Bridges" that you wish to use. If you're a c-Bridge
 | |
| person, think of these as "bridge groups". You might also liken them to a "reflector". If a particular
 | |
| system is "ACTIVE" on a particular conference bridge, any traffid from that system will be sent
 | |
| to any other system that is active on the bridge as well. This is not an "end to end" method, because
 | |
| each system must independently be activated on the bridge.
 | |
| 
 | |
| The first level (e.g. "WORLDWIDE" or "STATEWIDE" in the examples) is the name of the conference
 | |
| bridge. This is any arbitrary ASCII text string you want to use. Under each conference bridge
 | |
| definition are the following items -- one line for each HBSystem as defined in the main HBlink
 | |
| configuration file.
 | |
| 
 | |
|     * SYSTEM - The name of the sytem as listed in the main hblink configuration file (e.g. hblink.cfg)
 | |
|         This MUST be the exact same name as in the main config file!!!
 | |
|     * TS - Timeslot used for matching traffic to this confernce bridge
 | |
|         XLX connections should *ALWAYS* use TS 2 only.
 | |
|     * TGID - Talkgroup ID used for matching traffic to this conference bridge
 | |
|         XLX connections should *ALWAYS* use TG 9 only.
 | |
|     * ON and OFF are LISTS of Talkgroup IDs used to trigger this system off and on. Even if you
 | |
|         only want one (as shown in the ON example), it has to be in list format. None can be
 | |
|         handled with an empty list, such as " 'ON': [] ".
 | |
|     * TO_TYPE is timeout type. If you want to use timers, ON means when it's turned on, it will
 | |
|         turn off afer the timout period and OFF means it will turn back on after the timout
 | |
|         period. If you don't want to use timers, set it to anything else, but 'NONE' might be
 | |
|         a good value for documentation!
 | |
|     * TIMOUT is a value in minutes for the timout timer. No, I won't make it 'seconds', so don't
 | |
|         ask. Timers are performance "expense".
 | |
|     * RESET is a list of Talkgroup IDs that, in addition to the ON and OFF lists will cause a running
 | |
|         timer to be reset. This is useful   if you are using different TGIDs for voice traffic than
 | |
|         triggering. If you are not, there is NO NEED to use this feature.
 | |
| '''
 | |
| 
 | |
| BRIDGES = {
 | |
|     'WORLDWIDE': [
 | |
|             {'SYSTEM': 'MASTER-1',    'TS': 1, 'TGID': 1,    'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'ON',  'ON': [2,], 'OFF': [9,10], 'RESET': []},
 | |
|             {'SYSTEM': 'CLIENT-1',    'TS': 1, 'TGID': 3100, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'ON',  'ON': [2,], 'OFF': [9,10], 'RESET': []},
 | |
|         ],
 | |
|     'ENGLISH': [
 | |
|             {'SYSTEM': 'MASTER-1',    'TS': 1, 'TGID': 13,   'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [3,], 'OFF': [8,10], 'RESET': []},
 | |
|             {'SYSTEM': 'CLIENT-2',    'TS': 1, 'TGID': 13,   'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [3,], 'OFF': [8,10], 'RESET': []},
 | |
|         ],
 | |
|     'STATEWIDE': [
 | |
|             {'SYSTEM': 'MASTER-1',    'TS': 2, 'TGID': 3129, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [4,], 'OFF': [7,10], 'RESET': []},
 | |
|             {'SYSTEM': 'CLIENT-2',    'TS': 2, 'TGID': 3129, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [4,], 'OFF': [7,10], 'RESET': []},
 | |
|         ]
 | |
| }
 | |
| 
 | |
| '''
 | |
| list the names of each system that should bridge unit to unit (individual) calls.
 | |
| '''
 | |
| 
 | |
| UNIT = ['ONE', 'TWO']
 | |
| 
 | |
| '''
 | |
| Unit Call flood timeout:
 | |
| The amount of time to keep sending private calls to a single system before
 | |
| flooding all systems with the call. A higher value should be set for systems where subscribers
 | |
| are not moving between systems often. A lower value should be set for systems that have subscribers
 | |
| moving between systems often.
 | |
| 
 | |
| Time is in minutes.
 | |
| '''
 | |
| UNIT_TIME = 1
 | |
| 
 | |
| '''
 | |
| Input the DMR ID and SYSTEM of a subscriber that you would like to have always have private calls routed.
 | |
| This will not flood all systems.
 | |
| '''
 | |
| STATIC_UNIT = [
 | |
|     [ 123, 'CLIENT-1'],
 | |
|     [ 456, 'CLIENT-1'],
 | |
|     [ 789, 'MASTER-1']
 | |
|     ]
 | |
| 
 | |
| 
 | |
| '''
 | |
| This is for testing the syntax of the file. It won't eliminate all errors, but running this file
 | |
| like it were a Python program itself will tell you if the syntax is correct!
 | |
| '''
 | |
| 
 | |
| if __name__ == '__main__':
 | |
|     from pprint import pprint
 | |
|     pprint(BRIDGES)
 | |
|     print(UNIT)
 |