From 5bc2417a7ed55b584f272179713040380f98522a Mon Sep 17 00:00:00 2001 From: Joe Taylor Date: Wed, 8 Jul 2020 11:34:32 -0400 Subject: [PATCH] Update User Guide to mention the new range for acceptable signal reports. --- doc/user_guide/en/protocols.adoc | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/doc/user_guide/en/protocols.adoc b/doc/user_guide/en/protocols.adoc index 625f63511..d9a7d8ada 100644 --- a/doc/user_guide/en/protocols.adoc +++ b/doc/user_guide/en/protocols.adoc @@ -38,8 +38,8 @@ FN42`, it means that s/he will listen on 50.290 and respond there to any replies.) A numerical signal report of the form `–nn` or `R–nn` can be sent in place of a grid locator. (As originally defined, numerical signal reports `nn` were required to fall between -01 -and -30 dB. Recent program versions accommodate reports between --50 and +49 dB.) A country prefix or portable suffix may be +and -30 dB. Program versions 2.3 and later accommodate reports between +-50 and +50 dB.) A country prefix or portable suffix may be attached to one of the callsigns. When this feature is used the additional information is sent in place of the grid locator or by encoding additional information into some of the 6 million available